<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-31 22-00-27
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 4/5, 73 dBuV NOSTALGI
Pilot RDS Phase Difference
6.1 kHz 3.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
7 kHz 65 kHz 10688 0,0094
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
5,2 dBr 5,93 dBr 6,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Gloria Gaynor - I will survive "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 65 kHz MIN: 7 kHz % above 76 kHz: 0,0094 Acquired: 2024/08/31 21.59.23 Total samples: 10688 Equivalent time: 0:08:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 6,7 dBr MIN: 5,2 dBr AVE: 5,93 dBr % above 12,2 dBr: 0,0 Last value: 5,6 dBr (2024/08/31 21.59.22) 21.46 21.48 21.50 21.52 21.54 21.56 21.58 0 2 4 6 Pm [dBr]